XL-CXL What type of wire or cable was used inside the XL and CXL type storage heater if it needs replacement?

• If the internal wiring loom cables were damaged and require replacement, the replacement cable must be a silicone rubber cable 1.5mm² conductor size rated to 180C.


• Any repair must be carried out by a suitably skilled person and any crimp connections must also be suitable to work to 180C and the operating current of the appliance.


• Insulated crimps which are identified red, yellow or blue are not suitable for this application and must not be used.


• The flex / cable going from the heater to the wall switch must be a 3 core 2.5mm² for off-peak with at least T85 minimum temperature rating.

Was this article helpful?

That’s Great!

Thank you for your feedback

Sorry! We couldn't be helpful

Thank you for your feedback

Let us know how can we improve this article!

Select atleast one of the reasons
CAPTCHA verification is required.

Feedback sent

We appreciate your effort and will try to fix the article